Deye Grid Tied Inverter SUN-3K-G04P1-EU-AM1 Single Phase
Thanks to the smart monitoring platform, Deye Grid Tied Inverter series inverter products offer the following benefits:
- Remote Shutdown: In the event of an accident, the inverters can be immediately shut down remotely, ensuring safety and preventing further damage.
- Remote Parameter Setting: Parameters can be easily adjusted remotely, providing flexibility and convenience for system management.
- Firmware Updates: Remote firmware updates allow for seamless upgrades, reducing the need for manual intervention and ensuring the system stays up-to-date.
These features significantly simplify the operation and maintenance (O&M) of PV plants.
MODEL | SUN-3K-G04P1-EU-AM1 |
---|---|
PV String Input Date | |
Max. PV Input Power | 3.9kw. |
Max. PV Input Voltage | 550v |
Start-up Voltage | 80v |
MPPT voltage range | 70-500v |
Rated PV Input voltage | 360v |
Max. Operating PV Input Current | 20A |
Max. Input Short Circuit Current | 30A. |
No. of MPP Trackers/No. of Strings? MPP Tracker | 1/1 |
No. of MPP trackers | 7 |
Output Data(AC) | |
Rated AC Output Active Power | 3kW |
Max. AC Output Apparent Power | 3.3kVa |
Rated AC output current | 13.7/13.1A |
Max. AC Output Current | 15/14.4A |
Rated output voltage/range | 220/230 0.85Un-1.1Un |
Grid Connection Form | L+N+PE |
THDi | <3% (@100% load). |
Rated Output Grid Frequency/Range | 50/45-55, 60/55-65HZ. |
DC Injection Current | <0.5%ln |
Max. Efficiency | 97.5%. |
MPPT Efficiency | >99% |
DC Polarity Reverse Connection Protection | Yes |
AC Output Overcurrent Protection | Yes |
DC Component Monitoring | Yes. |
Ground Fault Current Monitoring | Yes |
Overvoltage Load Drop Protection | Yes |
Communication Interface | RS485/RS232. |
Operating Temperature Range | -25 to +65℃, >45℃ Derating |
Permissible Ambient Humidity | 0~100% |
Permissible Altitude | 2000m |
Dimensions (W/H/D) | 280mm*310mm*184mm |
Weight | 6.35kg |
Noise | ≤ 35 dB |
Type Of Cooling | natural cooling. |
Operating temperature range | –30 °C~60 °C (> 50°C, derating). |
Inverter Topology | Non-Isolated. |
Over Voltage Category | OVC II(DC),OVC III(AC). |
Ingress Protection(IP) Rating | 65 |
Warranty | 5 Years. |
Safety / EMC standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2. |